BT35-0.75KW380V璧式崗位式管道式防爆軸流風機
采用BT35防爆軸流風機,需在出風口中連接管道時,必須考慮與管道連接方式,以減少通風機的動壓在接管段因擴散
而造成的損失。
When connecting the pipes to the outlet of the BT35 explosion-proof axial flow fan, take account of the connection wayto reduce the losswhich caused by dynamic pressure of ventilator in the a connected pipe.
1.當管道 直徑與通風機桶相等時,管道的擴散損失可忽略不計(如圖1);
2.當 ≤1.5時而管道長度小于管內徑5~8倍時,可不加擴散器(如圖2);
3.當1.5≤ <2.5時,管道與通風機應安裝如圖所示型式之擴散器(如圖3);
4.當 >2.5時,管道與通風機應安裝如圖所示型式之擴散器(如圖4)。
1.When the diameter of the pipe is equal to that of ventilator barrel, the lossof diffusion in pipecan be omitted(As shown in fig 1);
2.When ≤1.nd the pipe is 5~8 times shorter than the internal pipediameter,the diffuser can be unset(As shown in fig 2);
3.When 1.5≤ <2.5,the diffuser as shown in the diagram shall be fittedto the pipeand ventilator (As shown in fig 3);
4.When >2.5,the diffuser as shown in the diagram shall be fitted to thepipe andventilator (As shown in fig 4).
BT35-0.75KW380V璧式崗位式管道式防爆軸流風機型號
BT35型軸流通風機依葉輪直徑的大小分為NO2.8、NO3.15、NO3.55、NO4、NO4.5、NO5、NO5.6、NO6.3、NO7.1、NO8、NO9、NO10、NO11.2十三種機號,每一種機號的葉片數都為4片。葉片又可裝成15°、20°、30°、35°五種角度。因此,每一機號由于葉片安裝角度的大小,主軸轉速快慢的不同,風機的風壓,風量及所消耗功率也不相同。 傳動方式:選用各級電動機,與葉輪直接聯接,機體外殼制成圓筒形,旋轉方向為順時針方向。 產品嚴格執行GB3836.1-2010《爆炸性環境 **部分 設備 通用 要求》和GB3836.2-2010《爆炸性環境 第二部分 用隔爆外殼“D"保護的部分》,該產品主要適用于石油化工、醫藥紡織、冶金機械、船舶倉儲等易燃易爆環境的通風降溫。本防爆軸流風機具體參數及詳情如下:
1、BT35系列防爆軸流風機扇葉采用4片鑄鋁合金材質一次性壓鑄成型扇葉(4#及以上扇葉采用鋁制扇葉片),經過6道機加工工序后,具有結構新穎、堅固耐用等特點;該防爆風機風筒采用3mmQ235鋼板經過一次性卷彎、焊接成型,表面靜電噴塑處理,具有一般性耐腐蝕特點;
2、’本防爆軸流風機安裝方式可根據現場情況分為以下三種:壁掛式:即根據防爆風機風筒外徑在相應的場所墻壁鑿與風筒直徑相等的孔,將防爆風機整體嵌入墻壁后用水泥澆筑,外面用膨脹螺絲二次固定即可;崗位式:根據現場需求,在防爆風機上面加裝一個可上下60°控制方向,此種安裝方式方便該防爆風機隨時移動及向不同的方向送風等功能;固定式:此種安裝方式是在防爆風機下方安裝一個固定支架,將防爆風機在地面固定送風,便于移動。崗位和固定式支架材質采用鋼板焊接成型,表面靜電噴塑。
產品特點
1,防爆軸流風機由防爆電機、扇葉、風筒等部分組成;
2,防爆軸流風機具有噪聲低、能耗低、防爆性能可靠;
3,壁式:風扇外形兩端一邊是喇叭口型,一邊是90°直角法蘭型;
4,管道式:風扇兩端都成直角法蘭邊,可以安裝在管道的中間;
5,崗位式:除具有壁式特征外,附加崗位腳架附件,風扇腰中打安裝孔φ12;
6,固定式:除具有局式特征外,底部焊接固定安裝架